• SO2 (Sulfur Dioxide)
  • UV Fluorescence
  • 0-10 ppm (configurable)
  • EN 14212, US-EPA, KECO, CNEMC
  • NO, NO2 (Nitrogen Oxide and Nitrogen Dioxide)
  • Chemiluminescence
  • 0-10 ppm (configurable)
  • EN 14212, US-EPA, KECO, CNEMC
  • CO (Carbon Monoxide)
  • IR gas filter correlation
  • 0-100 ppm (configurable)
  • EN 14212, US-EPA, KECO, CNEMC
  • O3 (ozone)
  • UV photometry
  • 0-1 ppm (configurable)
  • EN 14212, US-EPA, KECO, CNEMC
  • TSP, PM10, PM2.5, PM1 (via inlet change)
  • Beta Gauge
  • Reliable mass measurement
  • Real time optical module available
  • Regulatory monitoring, research
  • EN 14212, US-EPA, KECO, CNEMC
  • TSP, PM10, PM2.5, PM1 (simultaneously)
  • Light scattering (nephelometry)
  • Real time, multi parameter device
  • Regulatory monitoring, research
  • EN 12341
  • THC, CH4, NMHC
  • Flame ionization detector (FID)
  • FID combined with catalytic methane cutter (optional)
  • Urban air toxics, industrial perimeter
  • Compliant to US-EPA and EN 12619 (for THC)
  • VOCs (BTEX, etc.)
  • Photo Ionization Detector + Gas Chromatography
  • Speciation capability, highly sensitive
  • Urban air toxics, industrial perimeter
  • Certified to EN 14662-3
  • Total reduced sulfur (TRS).
  • UV fluorescence after conversion.
  • Based on AF22e with thermal converter in an external rack for TRS.
  • Odor monitoring, pulp & paper, water treatment, waste management, petrochemicals. Based off reference method.
  • H2S (hydrogen sulfide)
  • UV fluorescence after conversion
  • Based on AF22e with built in thermal converter for H2S
  • Odor monitoring, pulp & paper, water treatment, waste management, petrochemicals
  • Based off reference method
  • Ammonia (NH3)
  • Chemiluminescence after conversion
  • Based on AC32e thermal converter in an external rack for NH3
  • Odor monitoring, pulp & paper, water treatment, waste management, petrochemicals
  • Based off reference method
  • NDIR-GFC multi-gas analyzer
  • Automated drift control option
  • Simultaneous multi-gas measurement of NOx, SO2, CO, O2, residual H2O, and optionally CO2, CH4 and N2O (greenhouse gases)
  • Environmental-friendly and cost-saving analyzer, with ultra-low power consumption
  • No compressed air required (if using a gas cooler)
  • QAL1 certified according to EN 15267, QAL3 compliance as defined by EN 14181, U.S. EPA Compliance (40 CFR PART 60 & 75)
  • Stack gas sampling system
  • Sampling probe equipped with double stage particulate filtration
  • Direct span and zero gas injection for a complete system calibration
  • Permeation-based drying system avoids loss of highly condensable gases (e.g. HCl, SO2, NO2 and HF)
  • To be used with unheated analyzers such as MIR 9000, MIR 9000e, MIR 9000CLD
  • Automatic back-flush function
  • Heated sampling system
  • Double stage dust filtration
  • Direct span and zero gas injection for a complete system calibration
  • Automatic back-flush function
  • To be used with heated analyzers such as MIR FT, MIR 9000H, Graphite 52M
  • 190°C heated sampling system without any modification of the gas matrix including water content
  • Heated sampling system
  • Stainless steel probe tube with optional reusable primary filter
  • Check valve eliminates dead volume
  • To be used with heated analyzers, or with unheated analyzers, such as MIR 9000, MIR 9000e, MIR-IS, by adding a cooling dryer
  • Single stage dust filtration
  • 190°C heated sampling system without any modification of the gas matrix including water content